Paper · https://arxiv.org/abs/2611.06979
arXiv:2611.06979v1 Announce Type: new Abstract: M/EEG source imaging requires accurate localization and reliable uncertainty estimates, yet posterior credible regions are rarely assessed for empirical calibration. We present a simulation-based framework for uncertainty quantification and calibration of empirical Bayesian inverse methods with closed-form conditional Gaussian posterior summaries. We compare Bayesian minimum norm (BMN) with sLORETA depth weighting and sparse Bayesian learning (SBL) with sparse basis field expansions (S-FLEX). S-FLEX allows retained coefficients to contribute nonzero marginal posterior variance at locations where voxel-wise SBL yields degenerate variances. For BMN, we derive joint source- and noise-variance updates through evidence maximization. We test whether adaptive noise learning yields near-calibrated uncertainties. Both methods retain residual miscalibration, motivating post-hoc isotonic recalibration of credible-region levels using empirical coverage. Simulations assess fixed- and free-orientation models across signal-to-noise ratios (SNR), source sparsity levels, and subject-specific head models, using oracle, baseline-estimated, and adaptively learned noise. Before recalibration, SBL+S-FLEX yields lower Wasserstein localization error, smaller posterior uncertainty, and coverage closer to nominal credibility than BMN+sLORETA. Isotonic recalibration improves both methods, with larger gains for conservative BMN+sLORETA posteriors; transfer across mismatched SNR, sparsity, and head models remains condition dependent. Noise specifications yield broadly consistent reconstruction and uncertainty trends within each estimator. In real auditory MEG data, SBL+S-FLEX provides more focal localization and tighter uncertainties than BMN+sLORETA, suggesting greater statistical power for identifying bilateral auditory sources.
First seen by Oriel on .
AI summary
This paper evaluates uncertainty calibration for Bayesian M/EEG source imaging, finding that SBL+S-FLEX generally outperforms BMN+sLORETA while isotonic recalibration improves both methods.
- The simulation framework assesses empirical coverage across orientation models, signal-to-noise ratios, sparsity levels, head models, and alternative noise specifications.
- S-FLEX lets retained coefficients retain nonzero marginal posterior variance where voxel-wise SBL produces degenerate variances.
- Before recalibration, SBL+S-FLEX achieves lower Wasserstein localization error, smaller posterior uncertainty, and coverage closer to nominal credibility than BMN+sLORETA.
- Isotonic recalibration improves both estimators, especially conservative BMN+sLORETA posteriors, but transfer across mismatched conditions remains dependent on the setting.
- In real auditory MEG data, SBL+S-FLEX produces more focal localization and tighter uncertainties, suggesting greater statistical power for bilateral auditory sources.
#m/eeg #bayesian inference #uncertainty calibration #source imaging
Generated by gpt-5.6-sol. Check the original for details.